AOTX-PRISMDOCUMENTATION
REFERENCE LIBRARY
Start here
On this page
  1. Choose how to connect
  2. Open a project
  3. Hold an ordinary conversation
  4. Use persistent conversations
  5. Open supporting windows
  6. Resume after interruption

First use#

PRISM opens a local workspace without starting a model. The connection strip reports gateway status. The project rail identifies where local history is stored. Choosing a folder does not grant a model access to its files.

Choose how to connect#

Available system Start here
A running local or remote gateway Open Connection and enter its URL and bearer token.
An installed local AOTX build Follow runtime setup, then select Connect owned runtime.
A complete shared CCIR file Follow activation, then open CCIR workspace.

Remote gateway URLs require HTTPS. HTTP is permitted for exact loopback addresses and localhost. An SSH tunnel can expose a remote gateway on loopback. Use the credential issued by its operator. PRISM does not retain that token on disk.

Open a project#

  1. Open Project.
  2. Select Browse folders or enter an existing folder path.
  3. Select Open project.
  4. Check the current folder shown in the project rail.

PRISM stores its history in the folder's private .prism directory. Disconnect before selecting another project. Projects and files explains archives, exports and backups.

Hold an ordinary conversation#

  1. Connect the gateway.
  2. Open Models and select an advertised model.
  3. Apply the output-token limit and temperature.
  4. Select + New conversation.
  5. Set the name and review the system prompt.
  6. Select Create conversation.
  7. Enter a message and select Send message.

The neutral default assigns no name or runtime role. Edit it before creation, or leave it blank. Use neutral default restores the supplied instructions. Existing conversations keep their original instructions.

The ordinary system prompt permits at most 4,096 UTF-8 bytes. This is a prompt field limit, not the model's total context capacity. The connected backend also limits the combined prompt and output. PRISM does not silently trim history.

Use Ctrl+Enter to send from the ordinary message box. Model output appears as received. Completed reports a terminal device result; the footer separately reports whether local history was saved.

Use persistent conversations#

Open CCIR workspace after connecting a complete shared runtime. Register the participant, select a space and select New CCIR conversation. The setup window lets you set its name and instructions before the first input.

Shared prompts require advertised support. The supported prompt field and each shared input have separate 2,048-byte limits. Instructions remain fixed for that conversation. Runtime memory rules and authenticated actor context still apply.

A shared result can be completed while its save is pending. Read the receipt, generation and pending bytes. Follow shared CCIR for scopes, permissions and saved-file recovery.

Open supporting windows#

Action Window
Select a model or save generation settings Models
Select qualified controls or permitted runtime settings Affect
Read project files Project files
Inspect memory and source references Windows > Memory evidence
Read background counters and events Windows > Activity

Panels can float, dock, resize and maximize. Closing a panel does not cancel its request. Choose silver or graphite with the theme selector. See interface controls for keyboard and layout details.

Resume after interruption#

Reopen the project and reconnect the same gateway when it is still available. Use Read result for an ordinary request with a retained handle. A submission with uncertain admission and no handle is not sent again automatically.

Shared operations retain an exact recovery identity. Inspect the receipt before using Retry exact request. This action differs from an ordinary resubmission. Recovery guidance explains both cases.

Closing PRISM stops its owned runtime. External runtimes continue under their operator's control. A local history entry alone does not establish a saved device result.

AOTX-PRISM / DOCUMENTATIONBack to top ↑
SEARCH DOCUMENTATION
Press Escape to close

Loading search...